Digital correction of current transformers non-linearity in microprocessor based meters of electric energy
Keywords:
energy, current transformer, methods of correction, expected value, interpolationAbstract
Digital correction methods of non-linearity input current converters in the electronic meters of electric energy is investigated. New method of obtaining of correcting function and technique of its statistical processing is developed. Heuristic algorithm of piece-linear interpolation with free limits of area determination is elaborated.Downloads
-
PDF (Українська)
Downloads: 67
Abstract views: 152
Published
2010-11-12
How to Cite
[1]
O. M. Zaslavskyi and V. V. Kukharchuk, “Digital correction of current transformers non-linearity in microprocessor based meters of electric energy”, Вісник ВПІ, no. 2, pp. 48–55, Nov. 2010.
Issue
Section
Energy generation and electrical engineering
License
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).